50 08/06
5.1.3 Characteristic
The mapping of the analog input signals onto a frequency or percentage reference
value is possible for various demands. The parameterization is to be done via two
points of the linear characteristic of the reference channel.
he characteristic point 1, with the coordinates X1 and Y1, and the characteristic point
2, with the coordinates X2 and Y2, can be set in four parameters.
he characteristic points X1 and X2 are stated as percenta
es, as the analo
input can
be switched as a current or voltage input via switch S3.
Parameter Setting
No. Description Min. Max. Fact. sett.
564 Characteristic point X1 -100.00 % 100.00 % -98.00 %
565 Characteristic point Y1 -100.00 % 100.00 % -100.00 %
566 Characteristic point X2 -100.00 % 100.00 % 98.00 %
567 Characteristic point Y2 -100.00 % 100.00 % 100.00 %
The coordinates of the characteristic points are related as a percenta
e to the analo
signal, with 10 V or 20 mA, and the parameter Maximum Frequency 419 or parame-
ter
Maximum reference percentage 519. The chan
e of direction of rotation can be
done via the digital inputs of the frequency inverter and/or by selecting the character-
istic points.
The definition of the analog input characteristic can be calculated via the two-poin
form of the straight-line equation. The speed Y of the drive mechanism is controlled
according to the analog control signal X.
()
Y1X1X
X1-X2
Y1-Y2
Y +−⋅=
Attention!
Monitoring of the analog input signal via the parameter
rror/Warnin
Behavior 563 demands a check of the characteristic parameters. Sensible
use is only possible if the
Characteristic point X1 564 is in the positive
range.