ACT401- 33 35 37 39
Size 6 (-, A)
Output, motor side
Recommended rated motor power P
n
kW 37.0 45.0 55.0 65.0
Rated motor current output I
n
A 75.0 90.0 110.0 125.0
Rated motor voltage output U
n
V 3 x (from 0 to mains voltage)
Overload current for 60 s I
pk
A 112.5 135.0 165.0 187.5
Overload current for 1 s I
pk
A 150.0 180.0 220.0 250.0
Switching frequency f
c
kHz From 2 to 8
Rated motor frequency f
n
Hz From 0 to 1000
Input, mains side
Nominal mains voltage U V 320 ... 528
Nominal mains frequency f Hz 45 ... 66
Nominal current 3 ph/PE I A 72 86 105 120
Mains fuses 3 ph/PE I A 80 100 125 125
General
Short circuit / ground fault protection - - Yes, unlimited
Mounting position - - Vertical
Protection class - - IP 20 (EN60529)
(0)
Dimensions Std. A
HxWxD
mm 400 x 275 x 260
Cold Plate Opt. C
HxWxD
mm
Weight (approx.) m kg 20
Environment
Cooling temperature T
n
°C From0to40(3K3DINIEC721-3-3)
Relative air humidity - % From 15 to 85, non-condensing
Derating P -
2.5%/Kabove40°C;Tmax=55°C;
5%/1000mabove1000minstallationaltitude;hmax=4000m
Options & accessories
Line choke - - External (depending on mains supply)
EMI filter - - External
Brake unit - - Internal brake transistor
Digital control unit - - Yes
Note: (0) = for protection classes higher than IP20 consult your local Bonfiglioli Drives Service Center